LAB GRUPPEN PLM10000Q

LAB GRUPPEN Ref : PLM10000Q


82,00 € HT

ampli 4 X 2500W + processeur 

 

General
Number of input channels 2
Number of output channels 4
Peak total output all channels driven 10800 W
Peak output voltage per channel 153 V
Max output current per channel 49 A peak
Max output power (all channels driven)
16 ohms 660 W
8 ohms 1300 W
4 ohms 2300 W 1
2 ohms 2350 W 1
All channels driven into optimal impedance interval > 2700 W into 2.4 - 3.2 ohms
Max output power bridged
8 ohms 4600 W
4 ohms 4700 W
Bridged into optimal impedance interval > 5400 W into 4.8 – 6.2 ohms
Performance
THD + N 20 Hz - 20 kHz for 1 W < 0.05 %
THD + N at 1 kHz and 1 dB below clipping < 0.04 %
Dynamic range with analog inputs >112 dB
Frequency response (1 W into 8 Ohm, 20 Hz - 20 kHz) +/- 0.05 dB
Common Mode Rejection (CMR) >74 dB, 20 Hz to 20 kHz
Internal Sample Rate / Data path 96 kHz / 32 bit floating point
Product propagation delay (straight path analog server input -> amp) 1.61 ms
Product propagation delay AES 96 kHz / analog input 1.68 ms
Sample Rate Converters
THD + Noise 0.00003 %, 20 Hz - 20 kHz, unweighted
Analog to Digital inputs
Inputs 2 inputs x 2 link
Input sensitivity settings +12 or +26 dBu
THD + Noise 0.00022 %, typical at 1 kHz unweighted at +26 dBu headroom setting
THD + Noise 0.00033 %, typical at 20 Hz and 20 kHz unweighted at +26 dBu headroom setting
Gain, Sensitivity and Limiters
Adjustable Inter-Sample Voltage Peak Limiter (ISVPL) 17.8 - 153 V, step size 0.1 V
Current Average Limiter (CAL) > 300 ms 25 Arms
MaxRMS (rms voltage limiter) Yes
MaxPeak (peak voltage limiter) Yes
Output attenuator -Inf to 0 dB, step size 0.25 dB
AES3/EBU (sample rate converters available as desired)
Supported sample rates 48, 96 kHz
Support redundant paths Yes
Flexible topology yes
Network latency 0.8, 1.3 and 4 ms
Back panel Interface
AES / EBU / I/O (input + link) 2 x 3-pin XLR
Analog, 2-channel I/O (input + link) 4 x 3-pin XLR, electronically balanced
Output connectors Neutrik speakON (1 x NLT8, 2 x NLT4) or 4 Binding Posts (pairs)
Auto 10/100, Auto Uplink 2 x RJ45 etherCON
Control and monitoring interface Via Ethernet for Lake Controller software, or DLM (the 3rd party protocol)
Detachable mains cord Neutrik PowerCon rated at 250V/32A
Cooling Two fans, front-rear airflow, temperature controlled speed
Front-panel user interface
Display 2.5 inch, daylight readable LCD
Fault/Warning/Limit/Clip indicators RGB LEDs and detailed fault description on display
Mute and soft function buttons 8 provided
Standby Power button On/Standby
Meter button Toggles through meter views
Menu Provides a menu driven interface for full function front panel control
Rotary Encoder Yes
Exit Button Provides a “back” function
Power
Operating voltage 140 - 265 V / 70 - 135 V 2
Soft start / Inrush power Yes / max. 5 A
Power Average Limiter (PAL) Yes
Power Factor Correction (PFC) No
Breaker Emulation Limiter (BEL) No
Under Voltage Limiter (UVL) No
Dimensions
Rack rail to rear panel W: 483 mm (19”), H: 88 mm (2 U), D: 386 mm (15.2”)
Weight
Weight 13.5 kg (30 lbs)